The MountV resources failed to come online on node1

Problem: The MountV resources failed to online on Cluster Node1

Cause: The MountV resources failed to probe on node1 because the volumes did not import successfully in VEA.

This is due to a PnP timeout as the volumes take long time to arrive

PS- Note that there are several fixes in SFW 5.1 SP2 addressing volume arrival timeout


Resolution

1- Symantec recycled the VM services (Vxob, actionagent, Vxvm and Vxgn)- However, VxVM was taking a long time to restart so we rebooted the node

2- Symantec Recommends that please upgrade Cluster nodes to SFW 5.1 SP2 for long term solution

Comments